Head Loss Coefficient K Table, Covering both rectangular and circular ducting, this material references many sources and provides the most commonly used items in each category. Head loss is unavoidable in real . Pressure Loss through a Pipe Fitting The pressure loss through a fitting (m hd or ft. A minor loss coefficient table lists the values of loss coefficients (K) for different fittings, valves, bends, and other components in a piping system, used to calculate pressure losses due to these minor losses in fluid flow. 174 ft/s² Pipe Fittings Database The head loss that occurs in the components of a flow path can be correlated to a piping length that would cause an equivalent head loss. Professional hydraulic calculator for engineering applications. Higher K values indicate greater friction losses. hd) is calculated using the 'K' factor as: Fitting Head Loss = Kv² / 2g where: K= K factor associated with a specific type and size of fitting v = fluid velocity (m/s or ft/s) g = 9. Pipe Fitting Loss Formula 3. , Essentially, one measures the pressure drop across the Although device, minor and forms loss coefficients the loss coefficient, can be determined k, using, analytically for certain situations, most frequently the loss = Δ p coefficient for a particular device is found experimentally. Examples are also given to demonstrate how to determine Loss coefficient, abbrevated as K, a dimensionless number, also called head loss coefficient or flow resistance coefficient, measures the minor loss to the change in velocity due to friction thru pipes, fittings, and valves. 806 m/s² or 32. Essentially, one measures the pressure drop Jul 31, 2025 · To calculate pressure loss and head loss due to fittings in a pipeline, engineers commonly use the K-factor method, which is based on the loss coefficient K of each fitting. Minor Loss Calculations This tool was developed to calculate head losses through valves and fittings in terms of the velocity head by using the applicable resistance coefficient K values. Note that the larger velocity (the velocity associated with the smaller pipe section) is used by convention in the equation for minor head loss, i. FITTING LOSS COEFFICIENTS This material provides coefficients for various fittings and loss-inducing components of a duct system. The K values can be used in formulas to calculate head loss (hf) from friction in fittings. 10 mm) as well as flow velocity (V in m/s). Minor Losses Here are some sample loss coefficients for various minor loss components. Apr 19, 2024 · Loss coefficients for pipe fittings and valves and how to calculate frictional head loss through fittings and valves. K coefficient for additional friction loss due to pipe and fittings The values below are only valid in TURBULENT FLOW Table 1 : K coefficient for calculation of pressure drop through valves and fittings Resistance Coefficient Method: Resistance coefficients are commonly reported by the manufacturers of liquid fittings and valves. The tables give the head loss per kilometer (j in m/km) for two values of the roughness coefficient (k = 0. This is the H2OCalc information for the Minor loss Equations. More values are listed in Table 8-4 of the Çengel-Cimbala textbook: Rounding of an outlet makes no difference. K coefficient for additional friction loss due to pipe and fittings The values below are only valid in TURBULENT FLOW Table 1 : K coefficient for calculation of pressure drop through valves and fittings As a result, loss coefficients are commonly determined experimentally through testing and correlated with pipe flow parameters, or obtained from established engineering references. The local pressure losses are classified in 2 categories: Those which are with For similar fittings, the K-value is highly dependent on things such as bend radius and contraction ratios. This yields a lower Re number and, according to Fig. Download Table | Head loss coefficients of this study from publication: Loss Coefficients for Periodically Unsteady Flows in Conduit Components: Illustrated for Laminar Flow in a Circular Duct and The local pressure losses corresponding by the valves and fittings in the hydraulic networks are expressed by the following relation: Dps = local pressure loss in Pa p = density of the fluid in kg/m3 V = rate of flow in m/s K = coefficient depend on the nature of local resistance = Dynamic pressure of the fluid. Sep 4, 2016 · Head loss due to Transitions and Fittings (Local loss) Introduction: H2OCalc is a hydrology and hydraulics calculator sold by Innovyze that has many of the equations and calculation methods used in #InfoSWMM, #ICM and #SWMM5. 1 Head loss, a larger pipe friction coefficient λ z (Note: the influence of the wall roughness can now often be ignored because of the larger boundary layer thickness in the flow). Calculate head loss in piping systems due to fittings and valves using K-values and velocity head method. Qu = flow from upstream pipe; Qo = flow out of pit; QL = flow from lateral pipes; Qg - flow from above the water level; k = pit head loss coefficient The pipes are assumed to operate below the water level in the pit. Minor Head Loss Pipe Entrance Pipe Fittings Loss Calculations with K Factors Pipe fittings, valves and bends usually have some associated K factor or local loss coefficient, which allows the calculation of the pressure loss through the fitting for a particular fluid flowing at a specified velocity. Manufacturers of pipe work fittings and valves often publish a fitting's associated 'K' factor. 3. Friction Loss Tables The K values given below are for making estimates of friction loss in cases not covered in the previous tables. It provides resistance coefficients (K values) for different pipe sizes and types of fittings like valves, elbows, tees, etc. Loss coefficient, abbrevated as K, a dimensionless number, also called head loss coefficient or flow resistance coefficient, measures the minor loss to the change in velocity due to friction thru pipes, fittings, and valves. e. Fittings such as elbows, tees, valves and reducers represent a significant component of the pressure loss in most pipe systems. 03 mm and k = 0. The document discusses friction losses in various pipe fittings. It is worth mentioning that the data, particularly for valves and fittings, depend on the specific manufacturer’s design. The following equations and Table 26 (or manufacturer’s data) can be used to calculate friction loss in terms of resistance coefficient. and is usually expressed as some coefficient (K) of the velocity head (M SHE). Most piping consists of more than just straight lines, these losses are termed a minor loss. Head Loss Head loss is a measure of the reduction in the total head (sum of elevation head, velocity head and pressure head) of the fluid as it moves through a fluid system. Pipe Fitting Loss Formula Resistance Coefficient Method: Resistance coefficients are commonly reported by the manufacturers of liquid fittings and valves. This article details the calculation of pressure losses through pipe fittings and some minor equipment using the K-value method, also known as the Resistance Coefficient, Velocity Head, Excess Head or Crane method. It also notes that the figures are applicable for water at 10 degrees C. May 22, 2019 · Resistance Coefficient Method – K Method The resistance coefficient method (or K-method, or Excess head method) allows the user to describe the pressure loss through an elbow or a fitting by a dimensionless number – K. Any bend or tee, expansion or contraction, valve opening or partially closing Dec 30, 2012 · Minor head loss is due to any pressure drop caused by an elbow, tee, valve, etc.